FBR-5060 Fire-Rated Uninsulated Access Door for Walls

The FBR-5060 is a fire-rated, uninsulated access door for wall applications where maintaining continuity in a 2-hour fire-rated wall is required.

Its 16-gauge steel or stainless steel door and frame sit flush to the frame with reinforced edges. A concealed hinge keeps hardware off the face of the door, and a universal self-latching bolt pulls the door closed and latches it automatically on contact. An inside latch release gives technicians a way out if the door closes while they're working behind the wall.

For walls, the FBR-5060 carries a UL 1-1/2 hour "B" label and a ULC 2-hour "B" label, and is listed to UL 10B, CAN/ULC S104, and NFPA 80.

Why Do Contractors Choose FBR-5060 Fire-Rated Uninsulated Access Door for Walls?

  • Fire rated for wall continuity: Carries a UL 1-1/2 hour "B" label and ULC 2-hour "B" label for walls, with compliance to UL 10B, CAN/ULC S104, and NFPA 80.
  • Self-latching on contact: The universal self-latching bolt engages automatically when the door closes, maintaining the fire-rated assembly without a separate manual latching step.
  • Self-closing: The door closes on its own after use, keeping the fire-rated wall assembly intact.
  • Removable door panel: The door panel is available in a removable configuration for projects requiring full, unobstructed access to the cavity.

Ready to order? Request a quote for the FBR-5060 to confirm sizing, material, latch options, and production lead times based on your project requirements.

Key Product Specifications

  • Application: Wall applications; designed to maintain continuity in a 2-hour fire-rated wall
  • Material: Steel or stainless steel
  • Door/frame: 16-gauge door, 16-gauge mounting frame; flush to frame with reinforced edges; flange 1" wide
  • Hinge: Concealed
  • Fire rating (walls): UL 1-1/2 hour "B" label; ULC 2 hour "B" label (optional); max sizes 36" x 48" and 24" x 79"
  • Standard compliances: UL 10B; CAN/ULC S104; NFPA 80
  • Standard latch: Universal self-latching bolt, operated by knurled knob or flush key
  • Lock option: Rim or mortise cylinder lock preparation (Master Keying), must be specified at time of order
  • Finish: Baked White Prime Coat (additional finish paint recommended for superior corrosion resistance)
  • Wall opening: Nominal door size plus 3/8" (9mm)
  • Standard sizes: 8" x 8" to 36" x 48"

Need a size that isn't on the standard list? Request a custom quote to get the FBR-5060 manufactured to your exact dimensions.

What Comes Standard and What Can Be Configured?

Every FBR-5060 ships with the following as standard:

  • 16-gauge steel door and 16-gauge mounting frame, flush to frame with reinforced edges
  • Concealed hinge
  • Universal self-latching bolt, operated by knurled knob or flush key
  • Inside latch release
  • Self-closing mechanism
  • Baked White Prime Coat finish
  • Removable door panel

The following must be specified at the time of order and is not included as standard:

  • Stainless steel construction
  • Rim or mortise cylinder lock preparation (Master Keying)

What Should You Confirm Before Ordering FBR-5060?

  • Wall opening size: The rough opening must be the nominal door size plus 3/8" (9mm). For instance, a 24" x 36" door requires a 24-3/8" x 36-3/8" wall opening.
  • Fire rating requirement: The FBR-5060 is rated for wall applications only. The maximum rated wall size is 36" x 48". If your opening exceeds this, confirm with our team whether a custom or alternative solution is available.
  • Temperature rise requirement: The FBR-5060 is uninsulated and designed for fire-rated wall continuity only when temperature rise is not a factor. If your assembly requires an insulated alternative, check out our other fire-rated panels to find the right fit.
  • Material: Choose steel for standard fire-rated wall applications. Choose stainless steel where corrosion resistance is required.
  • Lock option: The standard latch operates with a knurled knob or a flush key. If your project requires master keying, specify the rim or mortise cylinder lock preparation at the time of order.
  • Production lead time: Lead time depends on size, material, and configuration. Request a quote to confirm production and ship dates.

Installation Notes

  • Cut the wall opening to the nominal door size plus 3/8" (9mm) before installation.
  • The flange is 1" wide. Confirm wall finish depth accommodates the flange on all four sides before installation.
  • The self-latching bolt engages automatically when the door closes. No manual latching step is required after installation.
  • The inside latch release allows the door to open from inside the wall cavity. Confirm this feature is accessible based on cavity depth and component layout after installation.
  • Additional finish paint is recommended after installation for superior corrosion resistance, particularly in humid or moisture-prone environments.

Who Installs FBR-5060 and Where Is It Used?

The FBR-5060 is specified by architects, contractors, and facility managers who need a fire-rated access point in wall assemblies where insulation isn’t a requirement, and code-compliant fire continuity must be maintained.

Common applications include:

  • Commercial buildings: Fire-rated access to mechanical, electrical, and plumbing components in offices, retail spaces, and common areas where the wall assembly is fire-rated.
  • Healthcare facilities: Code-compliant fire-rated access in hospitals, clinics, and care facilities subject to NFPA 80 requirements.
  • Institutional buildings: Fire-rated access points in schools, government buildings, and other occupancies with UL 10B and CAN/ULC S104 compliance requirements.
  • Multifamily and residential buildings: Fire-rated access in corridor and utility walls in buildings subject to fire-rated wall continuity requirements.
  • Renovation and retrofit projects: Fire-rated access added to existing wall assemblies where the opening size falls within the rated maximum.

Frequently Asked Questions

1. How do I calculate the wall opening for FBR-5060?

Add 3/8" (9mm) to the nominal door size on each dimension. For example, a 24" x 36" door requires a 24-3/8" x 36-3/8" wall opening. This applies to all standard sizes.

2. What is the fire rating for FBR-5060?

The FBR-5060 carries a UL 1-1/2 hour "B" label and a ULC 2-hour "B" label for wall installations. It is listed to UL 10B, CAN/ULC S104, and NFPA 80.

3. Is FBR-5060 rated for ceiling installations?

No. The FBR-5060 is rated for wall applications only.

4. Does the door latch automatically?

Yes. The universal self-latching bolt engages when the door closes. No separate manual latching step is required. The latch operates with a knurled knob or flush key and releases from inside the wall cavity.

5. Can I order a custom size?

Yes. Custom sizes are available on request. Contact our team before ordering to confirm dimensions, fire rating applicability, and lead time.

Why Buy FBR-5060 From Acudor Access Panels?

Acudor Access Panels is an authorized Acudor distributor. Every FBR-5060 we supply is manufactured to Acudor's published specifications and carries the listed UL, ULC, and NFPA compliance ratings. Our team confirms sizing, fire-rating requirements, latch configurations, and production lead times for your specific order before you commit.

Have any questions? Contact our team or call +1-888-327-5471 to confirm specifications, compare sizes, and get guidance from our specialists.

download

Stay up to date with everything Acudor

Get the latest news, product announcements, and deals right to your inbox. Subscribe today!